Description

37 Isolated Standard Signal Conditioner | Input 0(4) … 20 mA | Ex | Transmission of HART signals | Loop-Powered

For safe-area/hazardous-area isolation of 0 ... 20 mA standard signals without power supply

  • Galvanic isolation between input and output signal
    Protection against measuring errors caused by grounding problems and parasitic interference voltages
  • No power supply required
    Cost savings due to lower wiring effort, no mains interference
  • Very low residual ripple
    No interference of the connected measuring or control system
  • Explosion protection according to ATEX
  • High transmission accuracy
    Excellent pulse formation due to exact transmission of the measured values
  • Very low common-mode interference
    Prevention of incorrect measurements or failures caused by interference
  • Maximum reliability
    No repair or failure costs
  • 10 kV test voltage
    (optional)
  • Protective separation according to EN 61140
    Protection of the maintenance staff and subsequent devices against excessively high voltages
  • SMART transmission
    Bi-directional point-to-point transmission of digital data according to the HART specification
  • 5-year warranty

Knick loop-powered isolators for 0 ... 20 mA signal transmission. These modules are available as hazardous-area input and hazardous-area output isolators. Due to their patented design (German patent 3526997), they are considered to be the most reliable solution for isolating standard signals without an external power supply.

The 37A7 isolators are not only suitable as highly reliable isolators for normal applications, they also meet the most stringent requirements that can be set for potential isolation. There is no need for power supply wiring.

We look forward to hearing from you!
Contact Us

Technical details

Communication (Output, Digital): HART
Product Category: Isolated Signal Conditioner
Device Type: Loop-Powered Isolators for Standard Signals
Explosion protection: Ex
Input: (±)20 mA, 4 … 20 mA
Output: 0 … 20 mA, 4 … 20 mA
Working Voltage, Min.: 50 V, 300 V, 1000 V, 2000 V
Test Voltage: 2.5 kV, 5 kV, 10 kV, 510 V
Fault Class: < 0.5 %
Housing: 17.5 … 67.5 mm Modular housing
Cutoff Frequency: < 1 kHz
Power Supply: Loop-Powered
Approvals: UL
Product Line: ProLine

Downloads

Manuals

[14276] User Manual (DE, EN)
37 Isolated Standard Signal Conditioner
Version 02

Brochures

[14160] Brochure
Product Overview Interface Technology

Certificates

[13687] EU Declaration of Conformity (DE, EN, FR)
WG 25 A7, Opt. ... & IsoTrans 37 A7, Opt. ...
No. EU210416A | 2021-04-16
WG25_37A7__PTB 02 ATEX 2063_Ausgabe1_e-8346343

Software

[11876] Knick Produktmakros (.pdf)
ePLAN Electric P8
[12154] Software (.zip)
ePLAN P8 Produktmakros

Our service

Used in Process or Applications

High voltage transducers and signal conditioners for the acquisition and conversion of current, voltage, temperature, speed, strain and resistance signals.

Relevant Blog Posts

ACHEMA 2024 Review

ACHEMA 2024 Review

Uniclean 700 Series - Modular control system for automated sensor cleaning

With the Uniclean 700 series, Knick is introducing a modular control system, that can be installed very quickly and cost-effectively as a flexible entry-level solution for automated sensor cleaning.

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology

Robust WA111 Retractable Fitting Made of Plastic for Highly Corrosive Operating Conditions

The plastic WA111 retractable fitting is a robust and cost-effective solution for corrosive processes and environments. It is equipped with a secure lock function and multiple nozzles for thorough sensor cleaning.

Successful joint project : Knick developed the special Ceramat WA 155 retractable fitting for optical probes from SOPAT

In cooperation with SOPAT, Knick developed a special Ceramat fitting for optical probes for automatic cleaning in fouling processes.

pH and conductivity measurement in vaccine production

Pharmaceutical contract manufacturer relies on Knick's transmitters for modular production plants for Covid-19 vaccines.

Sturdy 2-Electrodes Conductivity Sensor SE625 with Coaxial Electrodes made of Titanium

The SE625 ensures reliable and accurate determination of the conductivity of ultrapure water in the semiconductor industry.

Sensor Adapter with Lock Function Enables Safe and Thorough Cleaning

Sensor adapter with locking gate for safety and thorough cleaning of sensors in the immersion fitting ARD75 without the need

Up to six Sensors on one Transmitter Protos II 4400 via Modul MSU4400-180

Users can now connect up to six Memosens sensors simultaneously.

ACHEMA 2022 - Knick at the world forum for the process industry

In August 2022, the international process industry met at the ACHEMA. Knick presented the cCare system and industrial applications in a new concept.

Combined pH- and ORP-Sensor SE555X/*-AMSN

Combined pH and ORP measurement in one sensor SE555 saves place and equipment costs for demanding requirements in the chemical industry, the food sector and for hygienic applications.

Ultra Compact Transmitter for Memosens Sensors

The new ultra compact MemoTrans MT201 transmitter plugs directly onto the Memosens sensor in the fitting and communicates via 4-20 mA HART protocol.

Conveniently configure transmitters offline on a PC - ProgaLog 4000

Conveniently configure all flexibly configurable Stratos Multi and Protos II 4400 transmitters offline, save settings, duplicate for further transmitters, and create documentation for audits.

New Stratos Multi E461N transmitter with Profinet

The interface enables continuous communication of process variables and predictive maintenance from the field level to all common process control systems.

Memosens 2.0: Evolution of digital data transfer

As one of the two initiators of Memosens, Knick is constantly developing the technology.

SE655X Digital and SE656X Digital - Digital Conductivity Sensors with Ex Certification

The SE655X digital and SE656X digital conductivity sensors with Memosens protocol are now also available with Ex certification.

ILMAC 2021 in Basel - Trade Show Review by Knick Schweiz AG

Knick Schweiz AG exhibited at ILMAC in Basel and gives a brief review of what it's like to have finally met customers at the show again.

Stratos Multi E401X- Multiparameter Transmitter for Hazardous Locations

The new Multiparameter Transmitter Stratos Multi E401X can now also be used in hazardous locations, installed in Ex Zone 2.

Stratos Multi E471 with EtherNet/IP for process optimization

EtherNet/IP communication protocol allows the transmitter to be easily integrated into Industrial Ethernet networks as PCS.

New SE656N digital conductivity sensor

New toroidal Digital Conductivity Sensor with a large measuring range and consisting of PFA for using in aggressive media

Transmitter for the process industry with PROFINET module

The PROFINET industrial Ethernet standard is becoming an increasingly important aspect of process engineering in the “Industry 4.0” environment.

High-quality immersion fitting for mobile applications

ARD 170 enables measurements even in deep water

Modular immersion fitting as an electrically conductive variant

Knick is expanding its portfolio of fittings for liquid analysis with additional electrically conductive (EL) variants.

New multiparameter transmitter Stratos Multi

Knick is launching the the next generation in its Stratos analyzer product line.

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.

Powerful compact analyzer boosts performance while reducing costs

It has long been common practice when taking pH/ORP, conductivity, and oxygen measurements that a fixed analyzer be mounted near the sensor. The analyzer serves several purposes.

High-Precision Conductivity Measurement at Extreme Temperature Differences

Pharmaceutical manufacturer, EVER Pharma Jena uses the extremely robust conductivity sensors SE605(H) and SE680 with Memosens technology from Knick.

The Big Three of the Process Industry: HART, FF, Profibus

Our Knick multi-parameter analyzers are now available with Profibus and FF interfaces. Even for hazardous areas.