Passer au contenu principal Passer à la recherche Passer à la navigation principale

SE555_default

Description

SE555_default

Digital, sterilizable pH sensor providing high reliability and precision.

  • Gel electrolyte, pressurized
  • Ceramic junction
  • Silver ion trap
  • Integrated temperature detector
  • pH glass with high impedance for high-temperature applications, low alkali error
  • CIP/SIP-capable, safe sterilization with temperature monitoring
  • Perfect galvanic isolation thanks to Memosens technology
  • No influence of humidity in the connector
  • Precalibration in the lab
  • Digital data transfer
  • Integrated sensor diagnostics

The SE555 digital pH sensor comes with a special pH glass with high impedance for high-temperature applications and a low alkali error. The sensor is CIP- and SIP-capable. The silver ion trap prevents silver sulfide precipitation and junction fouling in media containing sulfides.

This makes the sensor ideal for routine applications in food processing and biotechnology. Additionally the Memosens technology offers all well known advantages concerning operation and sensor diagnostics.

Applications
Fermentation, food and beverages, aggressive media, extreme pH values

Nous attendons avec impatience votre réponse!
Nous Contacter

Détails techniques

Tête enfichable: Memosens

Téléchargements

Manuals

[12389] Manuel utilisateur
SE555X/*-AMSN | -NMSN | -NVPN | -NS8N
Version 04
[14165] User Manual | Betriebsanleitung
ZU1054 Sensor Protection | Sensorschutz
Version 01

Brochures

[13395] Brochure
Sondes - Pour la mesure du pH/redox, de la conductivité et de l’oxygène. Numérique et analogique.

Certificats

[14155] Declaration of Compliance 2.1 (DE, EN)
according to EN 10204 | gemäß EN 10204

Safety guides

[11049] Fiche de sécurité
Solution tampon CaliMat pH 2,00
[11045] Fiche de sécurité
Solution tampon CaliMat pH 7,00
[11048] Fiche de sécurité
Solution tampon CaliMat pH 4,00
[11044] Fiche de sécurité
Solution tampon CaliMat pH 12,00
[11046] Fiche de sécurité
Solution tampon CaliMat pH 9,00

Notre service

Lorem lorem ipsum ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

Utilisé dans les processus ou les applications

Cooling towers are used in a range of industrial sectors for diverting process heat from cooling circuits. Mineral deposits and corrosion reduce efficiency and lead to the premature wear of system components.
The taste and quality of beer greatly depend on the quality of the water used to brew it. pH and conductivity measurements determine its quality. Globalization is putting massive competitive pressure…
pH sensors are subject to extreme requirements during sugar production. Lime is dosed based on pH measurement right from the start...
Cooling towers are used in a range of industrial sectors for diverting process heat from cooling circuits. Mineral deposits and corrosion reduce efficiency and lead to the premature wear of system components…
High quality requirements are placed on raw milk, and online monitoring of truck unloading procedure at the dairy prevents inferior quality (sour milk) from spoiling the entire stock of the storage tank.

Articles de blog pertinents

Robust WA111 Retractable Fitting Made of Plastic for Highly Corrosive Operating Conditions

The plastic WA111 retractable fitting is a robust and cost-effective solution for corrosive processes and environments. It is equipped with a secure lock function and multiple nozzles for thorough sensor cleaning.

Coopération réussie : Knick a développé un support rétractable spécial Ceramat WA 155 pour les sondes optiques de SOPAT.

Nettoyage automatique des sondes optiques dans les processus d'encrassement : Un projet commun de Knick et SOPAT pour une application client avec Ceramat.

Canne d’immersion haute qualité pour applications mobiles

Avec l’ARD 170, Knick propose une canne d’immersion haute qualité pour mesures mobiles du pH, de la conductivité et de l’oxygène dissous. Les développeurs ont accordé une attention particulière à la simplicité et la flexibilité d’utilisation.

Canne d'immersion modulaire en version électriquement conductrice

Avec ses cannes d'immersion ARD 50 EL et ARD 75 EL, Knick complète de deux versions électriquement conductrices (EL) son portefeuille de cannes d’analyse de liquides. Les modulaires permettent l’utilisation de sondes spécifiques aux applications.

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.