Universal transmitters for temperature, strain gauges and potentiometers - in a 6-mm housing with infrared interface and SIL approval.

  • Universal usability from simple to challenging measurement tasks with all known temperature sensors, strain gauges, potentiometers, and similar sensors
  • Convenient setting of all parameters via IrDA interface – uncomplicated, menu-guided adjustment also “on site” including archiving of the configuration data
  • Intuitive configuration of the basic parameters – easily, without tools, using 4 rotary and 8 DIP switches
  • Calibrated range selection without complicated adjustment
  • Automatic detection of the sensor connection (2-, 3- or 4-wire)
  • Simulation of any desired output values for correct installation/commissioning
  • Protective separation according to EN 61140 – protection of the maintenance staff and subsequent devices against excessively high voltages up to 300 V AC/DC
  • Functional safety up to SIL 2 (up to SIL 3 in the case of redundant configuration) with TÜV certificate – systematically devel-oped according to EN 61508
  • High accuracy with innovative switching concept
  • Reduced inventory – one transmitter covers all conceivable tasks
  • Minimum space requirement in the enclosure – only 6 mm wide modular housing – more transmitters per meter of mounting rail
  • 5-year warranty

The P32000 universal transmitters provide connection possibilities for all standard thermocouples, resistance ­thermometers, strain gauges, full bridges, resistors and potentiometers/resistive sensors. They can be flexibly adapted to the respective measuring task using DIP and rotary encoder switches or via an IrDA interface.

3-port isolation with protective separation up to 300 V AC/DC according to EN 61140 ensures optimum protection of personnel and equipment as well as unaltered transmission of measurement signals. The P32000 offer maximum performance in the smallest of spaces. Resistance thermometers can be operated in 2-, 3- or 4-wire configuration. The connection configuration is automatically recognized, adjustment is not required. All commercial ­thermocouples can be read with internal or external ­reference junction compensation. To detect mechanical quantities such as force or strain, strain gauges can be connected in full-bridge configuration.

The ability to connect variable resistors and potentiometers creates a wide range of application possibilities, for example in the ­field of displacement or position detection. Input voltage signals up to +/– 1000 mV are converted into 0/4 to 20 mA or 0 to 10 V standard signals. This enables low-cost implementation of current measurements using shunt ­resistors, for example.

Knick offers the P32000 transmitter with SIL approval for applications with high demands on functional safety. The requirements of EN 61508 were implemented through specially developed hardware and software. The implemented fail-safe concept makes use of structural measures at the device level (redundancy of system components) and diagnostic ­methods for selective fault detection. The product is SIL2 approved (EN 61508) by an authorized body (TÜV Rheinland). SIL3 in redundant implementations.

We look forward to hearing from you!
Contact Us

Technical details

Input: (±)500 mV ... (±)200 V, Resistance Thermometers, Resistors / Potentiometers, Strain Gauges / Load Cells, Thermocouples, ≤ (±)500 mV
Output: 0 … 10 V, 0 … 20 mA, 4 … 20 mA, ±10 V, ±20 mA
Working Voltage, Min.: 50 V, 300 V
Test Voltage: 2.5 kV, 510 V
Fault Class: 0.1 %, < 0.5 %
Housing: 6 mm Modular housing
Cutoff Frequency: < 1 kHz
Power Supply: 24 V DC
Approvals: CSA, SIL, UL

Downloads

Manuals

[13390] User Manual (DE, EN, FR, ES)
ZU 0677 (Power terminal block)
Version 03
[1362] User Manual
P32000 P0/
Version 03
[1363] User Manual
P32000P0/11-KTA
Version 04

Brochures

[14160] Brochure
Product Overview Interface Technology

Data Sheets

[1352] Data Sheet
P32000 Universal Transmitter
Product Description | Specifications | Product Range

Certificates

[11418] Certificate of Compliance (UL)
No. 20181015-E220033 | 2018-OCTOBER-15
POWER CIRCUIT AND MOTOR-MOUNTED APPARATUS
P32*00P0/**, A202*0P0..., BL520
[11256] CB Test Certificate
No. DE 2-036775 | 2022-10-11
P32000, P32100, P32200, P32300, A20210, A20220, A20230
[13789] EU Declaration of Conformity (DE, EN, FR)
A20210P0, P32100P0, A20220P0, P32200P0, A20230P0, P32300P0, P32000P0
No. EU231123A | 2023-11-23
[11665] TÜV Rheinland Certificate
No. 968/EZ 272.00/07 | 2007-10-12
Transmitter Series P32*** P0/1
EN 61508 |SlL2, SIL3

Safety guides

[1383] SIL Safety Manual
P32*00P0/1
Version 02

Software

[11876] Knick Produktmakros (.pdf)
ePLAN Electric P8
[12155] Paraly SW 111
Parameterization Software
for P32x00 via IrDA Interface
[12154] Software (.zip)
ePLAN P8 Produktmakros

Our service

Used in Process or Applications

High voltage transducers and signal conditioners for the acquisition and conversion of current, voltage, temperature, speed, strain and resistance signals.

Relevant Blog Posts

ACHEMA 2024 Review

ACHEMA 2024 Review

Uniclean 700 Series - Modular control system for automated sensor cleaning

With the Uniclean 700 series, Knick is introducing a modular control system, that can be installed very quickly and cost-effectively as a flexible entry-level solution for automated sensor cleaning.

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology

Robust WA111 Retractable Fitting Made of Plastic for Highly Corrosive Operating Conditions

The plastic WA111 retractable fitting is a robust and cost-effective solution for corrosive processes and environments. It is equipped with a secure lock function and multiple nozzles for thorough sensor cleaning.

Successful joint project : Knick developed the special Ceramat WA 155 retractable fitting for optical probes from SOPAT

In cooperation with SOPAT, Knick developed a special Ceramat fitting for optical probes for automatic cleaning in fouling processes.

pH and conductivity measurement in vaccine production

Pharmaceutical contract manufacturer relies on Knick's transmitters for modular production plants for Covid-19 vaccines.

Sturdy 2-Electrodes Conductivity Sensor SE625 with Coaxial Electrodes made of Titanium

The SE625 ensures reliable and accurate determination of the conductivity of ultrapure water in the semiconductor industry.

Sensor Adapter with Lock Function Enables Safe and Thorough Cleaning

Sensor adapter with locking gate for safety and thorough cleaning of sensors in the immersion fitting ARD75 without the need

Up to six Sensors on one Transmitter Protos II 4400 via Modul MSU4400-180

Users can now connect up to six Memosens sensors simultaneously.

ACHEMA 2022 - Knick at the world forum for the process industry

In August 2022, the international process industry met at the ACHEMA. Knick presented the cCare system and industrial applications in a new concept.

Combined pH- and ORP-Sensor SE555X/*-AMSN

Combined pH and ORP measurement in one sensor SE555 saves place and equipment costs for demanding requirements in the chemical industry, the food sector and for hygienic applications.

Ultra Compact Transmitter for Memosens Sensors

The new ultra compact MemoTrans MT201 transmitter plugs directly onto the Memosens sensor in the fitting and communicates via 4-20 mA HART protocol.

Conveniently configure transmitters offline on a PC - ProgaLog 4000

Conveniently configure all flexibly configurable Stratos Multi and Protos II 4400 transmitters offline, save settings, duplicate for further transmitters, and create documentation for audits.

New Stratos Multi E461N transmitter with Profinet

The interface enables continuous communication of process variables and predictive maintenance from the field level to all common process control systems.

Memosens 2.0: Evolution of digital data transfer

As one of the two initiators of Memosens, Knick is constantly developing the technology.

SE655X Digital and SE656X Digital - Digital Conductivity Sensors with Ex Certification

The SE655X digital and SE656X digital conductivity sensors with Memosens protocol are now also available with Ex certification.

ILMAC 2021 in Basel - Trade Show Review by Knick Schweiz AG

Knick Schweiz AG exhibited at ILMAC in Basel and gives a brief review of what it's like to have finally met customers at the show again.

Stratos Multi E401X- Multiparameter Transmitter for Hazardous Locations

The new Multiparameter Transmitter Stratos Multi E401X can now also be used in hazardous locations, installed in Ex Zone 2.

Stratos Multi E471 with EtherNet/IP for process optimization

EtherNet/IP communication protocol allows the transmitter to be easily integrated into Industrial Ethernet networks as PCS.

New SE656N digital conductivity sensor

New toroidal Digital Conductivity Sensor with a large measuring range and consisting of PFA for using in aggressive media

Transmitter for the process industry with PROFINET module

The PROFINET industrial Ethernet standard is becoming an increasingly important aspect of process engineering in the “Industry 4.0” environment.

High-quality immersion fitting for mobile applications

ARD 170 enables measurements even in deep water

Modular immersion fitting as an electrically conductive variant

Knick is expanding its portfolio of fittings for liquid analysis with additional electrically conductive (EL) variants.

New multiparameter transmitter Stratos Multi

Knick is launching the the next generation in its Stratos analyzer product line.

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.

Powerful compact analyzer boosts performance while reducing costs

It has long been common practice when taking pH/ORP, conductivity, and oxygen measurements that a fixed analyzer be mounted near the sensor. The analyzer serves several purposes.

High-Precision Conductivity Measurement at Extreme Temperature Differences

Pharmaceutical manufacturer, EVER Pharma Jena uses the extremely robust conductivity sensors SE605(H) and SE680 with Memosens technology from Knick.

The Big Three of the Process Industry: HART, FF, Profibus

Our Knick multi-parameter analyzers are now available with Profibus and FF interfaces. Even for hazardous areas.