Passa al contenuto principale Salta alla ricerca Passa alla navigazione principale

SE554_default

Description

SE554_default

Low-maintenance sensor for demanding process applications in the chemical industry, digital, with Memosens technology

  • Höhere Betriebstemperatur
  • Erweiterte Ex-Zulassung
  • Diagnose Belastungsmatrix u. Statistik

 Bisheriger Text:

  • Simultaneous measurement of pH and ORP
  • Perfect galvanic isolation thanks to Memosens technology
  • No influence of humidity in the connector
  • Precalibration in the lab
  • Digital data transfer
  • Integrated sensor diagnostics
  • Low maintenance, no refilling of electrolyte
  • Integrated temperature detector
  • Open junctions, no blocking

The special design provides high accuracy, stability, speed, and a long life cycle. Through 2 open junctions, the reference system is in direct contact with the measured medium. There is hardly any risk of contamination or blocking of the junction. The high content and special distribution of potassium chloride in the polymer reduces measurement disturbances which could be caused by liquid junction potentials.

Applications
Measurement in media of extremely high ionic strength, salt brines, strongly oxidizing media, acidic and alkaline media

Non vediamo l'ora di ascoltarvi!
Contatto

Dettagli tecnici

Connettore: Memosens
Lunghezza: 120 mm
Parametro di misurazione: pH, pH/Redox, Redox
Protezione contro le esplosioni: Ex

Scaricamento

Manuals

[14165] User Manual | Betriebsanleitung
ZU1054 Sensor Protection | Sensorschutz
Version 01
[16286] User Manual (DE, EN, KO)
Memosens Cable CA/MS
Version 09

Brochure

[13395] Opuscolo
Sensori - Per la misurazione del valore di pH/Redox, conduttività e ossigeno. Digitale ed analogico.

Schede tecniche

[12872] Scheda tecnica
Sensore di pH/Redox SE554X/*-AMSN Memosens
Descrizione del prodotto | Specifiche | Gamma di prodotti

Certificati

[18254] Manufacurer's Declaration
Confirmation of the Compatibility of Digital Sensors from Our Company
Identifier: -B1
[12781] EU Declaration of Conformity (DE, EN, FR)
No. EU210706D | 2021-07-06
Memosens Measuring Cable Type CA/MS-...X.., CA/MS-...X..-L
[18270] Certitficate of Conformity (China - Ex NEPSI)
Cert No. GYJ24.1052X
SE5aa X/b-*MS*-B1
2024-04-03
[18286] Certificate of Conformity (FM)
No. FM23CA0070X | 2024-04-16 | Canada
Memosens Sensors | Types SE 5**X/*-*MS*-B1 (pH/ORP)
[14155] Declaration of Compliance 2.1 (DE, EN)
according to EN 10204 | gemäß EN 10204
O-Ringe aus EPDM oder Silikon | O-rings made of EPDM or Silicone
[12826] EU-Type Examination Certificate (DEKRA)
Nr. BVS 16 ATEX E 037 X | 2024-02-20
Memosens-Ex-Sensors
[18294] IECEx Certificate of Conformity
No. IECEX DEK 22.0019X
Issue No. 1 | 2025-01-09
Memosens, types SE5**X/*−*MS*−B1, SE605*-X*MS****… and SE625-X*MS*******…
[18262] EU Declaration of Conformity (DE, EN, FR)
Sensors Types SE5**X/*-*MS*-*B1
EU230912A | 2025-04-30
[18278] Certificate of Conformity (FM)
No. FM23US0105X | 2024-04-16 | USA
Memosens Sensors | Types SE 5**X/*-*MS*-B1 (pH/ORP)

Safety guides

[11046] Material Safety Data Sheet
CaliMat buffer solution pH 9,00
[11044] Material Safety Data Sheet
CaliMat buffer solution pH 12,00
[11049] Material Safety Data Sheet
CaliMat buffer solution pH 2,00
[11045] Material Safety Data Sheet
CaliMat buffer solution pH 7,00
[11048] Material Safety Data Sheet
CaliMat buffer solution pH 4,00

Control Drawings

[18302] Control Drawing
Memosens pH Sensors Type SE5**X/*−*MS*−B1
Zeichnungsnummer 213.215-066 page 1b rev.1
ATEX, IECEx

Servizio Unser

Lorem lorem ipsum ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

Utilizzato nei processi o nelle applicazioni

Misurazione del pH nel pre-scrubber, nella neutralizzazione e nello scrubber a calce all'interno del processo di desolforazione dei gas di scarico nelle centrali elettriche.
The taste and quality of beer greatly depend on the quality of the water used to brew it. pH and conductivity measurements determine its quality. Globalization is putting massive competitive pressure…
Le torri di raffreddamento sono utilizzate in diversi settori industriali per deviare il calore di processo dai circuiti di raffreddamento. I depositi minerali e la corrosione riducono l'efficienza e portano all'usura prematura dei componenti del sistema...
Depending on the sector, industrial wastewater is polluted by heavy metals, grease, oil, alkaline substances or, as in the paper and soap sectors, organic substances that can only be neutralized or separated with great effort.

Post rilevanti del blog

Ultra Compact Transmitter for Memosens Sensors

The new ultra compact MemoTrans MT201 transmitter plugs directly onto the Memosens sensor in the fitting and communicates via 4-20 mA HART protocol.