메인 콘텐츠로 건너뛰기 검색으로 건너뛰기 메인 메뉴로 건너뛰기

프로세스 분석

Flue gas desulfurization

To remove the corrosive SO2-gas from fossil fuel or waste power plant off gas, a wet scrubber process is used. Limestone, quicklime or calcium hydroxide is used to absorb the SO2 by forming gypsum which can be reused in building materials. Critical in this process is an accurate pH measurement to ensure complete removal of SO2 to meet government standards for clean air.

Keyfacts Application

Sector

Power plants with flue gas scrubber units

Application

3 Applications:

  1. Check pH in pre-scrubber
  2. Neutralization
  3. Lime Scrubber

Measured Parameter

pH

Key Requirements

The Locations of the measurement points are corrosive and heavy incrustations are formed.

Measuring in processes that build up thick layers of gypsum

Application Description

Application 1:

In the pre-scrubber (1st stage) the hot flue gas is cooled by injecting milk of lime. The pH value is only slightly increased (typically between pH 1–2 at 80 °C). Here, the pH must not rise above 2 because only HCl / HF and heavy metals are to be precipitated but SO2 binding is to occur at the second stage. Accurate pH control is essential. 

Application 2:

In the second stage, the main scrubber, the pH is increased by further addition of lime. SO2 is bound. Here, the lime milk addition must be controlled by continuous pH measurement. When the pH values are too high, too much lime has been added (increased costs) and the gypsum is polluted by excess calcium hydroxide. When the pH values are too low, the binding of SO2 is less efficient.

The optimum lies between pH 5.5 and 6.0. Higher values lead to soft and greasy calcium sulfite coatings (soft plugging) at slightly reduced efficiency. Lower pH values cause heavy incrustations which are difficult to remove (hard scale formation). Generally, the pH measuring point lies in the backflow circulation line of the calcium sulfite / gypsum sludge.

Application 3:

The excess water remaining after precipitation / thickening of the gypsum must be subjected to a neutralization procedure. For that purpose, sulfuric acid is added to bind the excess lime. Also, at this measuring point, there are heavy incrustations and deposits.

All 3 measuring points are extremely important to run the process in optimal condition. The locations are corrosive and heavy incrustations are formed, resulting in high maintenance. Knick recommends fully automated cleaning and calibration systems for these applications to reduce manual labor and increase process safety.

Requirements of Application

The immense challenge of this application is building up thick layers of gypsum in the gas scrubber units.

Why Knick ?
Ceramat is the only fitting which can be used due to the unique ceramic sealing. Deposit remover (“Pump Sock”) for Ceramat can remove deposits, which would otherwise clog the system completely. The unique Sensor Maintenance System cleans and calibrates the sensor fully automatically and reduces the maintenance efforts tremendously.

Related Industries and Applications

In power plants, water is used in many processes with completely different requirements, e.g. for steam generation, cooling and flue gas cleaning.
Cooling towers are used in a range of industrial sectors for diverting process heat from cooling circuits. Mineral deposits and corrosion reduce efficiency and lead to the premature wear of system components.
Measuring of pH, dissolved oxygen and conductivity in boiler feed water, steam and condensate in combined cycle gas turbine in power plants.
Measuring of pH, dissolved oxygen and conductivity as the essential parameters in boiler feed water circuits. The challenge of this application is the low ion concentration.
Since steam generator functions are critical to applications and their downtime or replacement is extremely cost intensive, it is important to avoid damage due to wear...
보일러 급수, 증기 및 응축수에서의 측정
Measuring of pH, dissolved oxygen and ORP in different applications while Water Treatment process of Power Plants’ Wastewater.
Reverse osmosis systems are used in a wide range of industrial applications for water treatment. The main application is industrial seawater desalination. Reverse osmosis…

Power Industry Brochure

Overview of energy-specific applications and product solutions

Download now

Blog Articles on this Subject

ACHEMA 2024 Review

ACHEMA 2024 Review

Uniclean 700 Series - Modular control system for automated sensor cleaning

With the Uniclean 700 series, Knick is introducing a modular control system, that can be installed very quickly and cost-effectively as a flexible entry-level solution for automated sensor cleaning.

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology

Robust WA111 Retractable Fitting Made of Plastic for Highly Corrosive Operating Conditions

The plastic WA111 retractable fitting is a robust and cost-effective solution for corrosive processes and environments. It is equipped with a secure lock function and multiple nozzles for thorough sensor cleaning.

Successful joint project : Knick developed the special Ceramat WA 155 retractable fitting for optical probes from SOPAT

In cooperation with SOPAT, Knick developed a special Ceramat fitting for optical probes for automatic cleaning in fouling processes.

pH and conductivity measurement in vaccine production

Pharmaceutical contract manufacturer relies on Knick's transmitters for modular production plants for Covid-19 vaccines.

Sturdy 2-Electrodes Conductivity Sensor SE625 with Coaxial Electrodes made of Titanium

The SE625 ensures reliable and accurate determination of the conductivity of ultrapure water in the semiconductor industry.

Sensor Adapter with Lock Function Enables Safe and Thorough Cleaning

Sensor adapter with locking gate for safety and thorough cleaning of sensors in the immersion fitting ARD75 without the need

Up to six Sensors on one Transmitter Protos II 4400 via Modul MSU4400-180

Users can now connect up to six Memosens sensors simultaneously.

ACHEMA 2022 - Knick at the world forum for the process industry

In August 2022, the international process industry met at the ACHEMA. Knick presented the cCare system and industrial applications in a new concept.

Combined pH- and ORP-Sensor SE555X/*-AMSN

Combined pH and ORP measurement in one sensor SE555 saves place and equipment costs for demanding requirements in the chemical industry, the food sector and for hygienic applications.

MemoTrans MT201N: Memosens 센서용 초소형 트랜스미터

새로운 초소형 MemoTrans MT201 트랜스미터는 피팅으로 Memosens 센서에 직접 연결하여 4-20 mA HART 프로토콜을 통해 통신합니다. pH, ORP, 산소 및 전도도 센서용 공간 절약형 솔루션입니다.

Profinet을 채택한 새로운 트랜스미터 Stratos Multi E461N

새로운 멀티 파라미터 트랜스미터 Stratos Multi E461N의 Profinet 인터페이스는 현장 레벨에서 시작하여 가장 많이 사용되는 공정 제어 시스템에 이르기까지 공정 파라미터와 예방적 유지 보수에 대한 연속적인 통신을 가능하게 합니다.

ProgaLog 4000 PC - 파라미터 설정 도구

단 하나의 파라미터 설정 도구 ProgaLog 4000만 사용하여 모듈식으로 설정 가능한 모든 트랜스미터 Stratos Multi 및 Protos II 4400을 오프라인으로 편리하게 파라미터를 설정하고, 설정을 저장하며, 다른 트랜스미터용으로 복제하고, 감사를 위해 문서화할 수 있습니다.

Memosens 2.0: Evolution of digital data transfer

As one of the two initiators of Memosens, Knick is constantly developing the technology.

SE655X 디지털 및 SE656X 디지털 - 방폭 인증을 받은 디지털 전도도 센서

Memosens 프로토콜을 채택한 전도도 센서 SE655X 디지털 및 SE656X 디지털은 이제 방폭 인증을 받은 제품으로 사용할 수 있습니다. 이 센서들은 재질과 설계로 인해 특히 화학, 제지 및 펄프 산업과 산업 폐수 모니터링에 적합합니다.

ILMAC 2021 in Basel - Trade Show Review by Knick Schweiz AG

Knick Schweiz AG exhibited at ILMAC in Basel and gives a brief review of what it's like to have finally met customers at the show again.

Stratos Multi E401X - 방폭 지역용 멀티 파라미터 트랜스미터

신제품 Stratos Multi E401X의 경우 구역 분리가 트랜스미터에서 바로 이루어지기 때문에 설치 시 별도로 특별한 방폭 액세서리가 필요하지 않습니다.

EtherNet/IP에서 Stratos Multi E471을 사용한 공정의 최적화

EtherNet/IP communication protocol allows the transmitter to be easily integrated into Industrial Ethernet networks as PCS.

새 디지털 전도도 센서 SE656N

New toroidal Digital Conductivity Sensor with a large measuring range and consisting of PFA for using in aggressive media

Transmitter for the process industry with PROFINET module

The PROFINET industrial Ethernet standard is becoming an increasingly important aspect of process engineering in the “Industry 4.0” environment.

(현장에서) 휴대용으로 사용할 수 있는 고품질의 침적식 피팅

저희 Knick Elektronische Messgeräte GmbH & Co. KG는 pH, 전도도 및 용존 산소의 휴대용 측정에 사용할 수 있는 침적식 피팅 ARD 170을 출시합니다. 제품을 설계 시, 간단하고 유연한 취급이 가능하도록 심혈을 기울였습니다.

방폭 지역에서의 사용을 위한 전기 전도성이 있는 버전의

저희 Knick Elektronische Messgeräte GmbH & Co. KG는 전기 전도성이 있는 버전(EL)의 침적식 피팅 ARD 50 EL 및 ARD 75 EL의 출시를 통해 액상 분석용 피팅의 포트폴리오를 확장했습니다. 이 2개의 산업용 피팅은 모듈식 구조로 되어있어 응용 분야에 맞는 센서를 선택할 수 있는 폭이 넓습니다.

액상 분석을 위한 새로운 지능형 멀티 파라미터 트랜스미터

저희 Knick社에서는 Stratos Multi를 통해 Stratos 분석 측정 기기의의 차세대 제품을 소개합니다. Stratos Multi는 지능적인 진단 관리를 제공해 드립니다. 일단 시중에 판매되고 있는 거의 모든 pH/ORP, 전도도 및 용존 산소 센서를 단 하나의 트랜스미터를 통해 확인할 수 있습니다.

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.

Powerful compact analyzer boosts performance while reducing costs

It has long been common practice when taking pH/ORP, conductivity, and oxygen measurements that a fixed analyzer be mounted near the sensor. The analyzer serves several purposes.

High-Precision Conductivity Measurement at Extreme Temperature Differences

Pharmaceutical manufacturer, EVER Pharma Jena uses the extremely robust conductivity sensors SE605(H) and SE680 with Memosens technology from Knick.

The Big Three of the Process Industry: HART, FF, Profibus

Our Knick multi-parameter analyzers are now available with Profibus and FF interfaces. Even for hazardous areas.