SE707 Oxygen Sensor | VP | 120 mm | Measuring range (resolution) 0 ... 50 mg/l (1 μg/l)

Description

SE707 Oxygen Sensor | VP | 120 mm | Measuring range (resolution) 0 ... 50 mg/l (1 μg/l)

Reliable measurement of oxygen traces, also under sterile and hygienic conditions; signal-stable and robust

  • high level of process safety
  • durable materials
  • robust design
  • easy to clean thanks to extremely smooth surface
  • very simple calibration in air without calibration gases
  • cost-efficient service due to easy-to-replace membrane module and interior body
  • hygienic design
  • very high resolution of 1 ppb in the trace range
  • low cross-sensitivity to CO2
  • operation also in hazardous locations
  • VP screw cap

High resolution of low oxygen concentrations, simple and cost-efficient sensor calibration in ambient air. No calibration gases. High signal stability, also in the presence of high CO2 partial pressures.

FDA-conforming material with extremely smooth polished surface. Simple maintenance due to modular design. Sterilizable, autoclavable, and CIP capable. Also suitable for hazardous locations.

Applications
Beverage filling (e.g. milk, beer), measurement in boiler feed water (detection limit 1 ppb)

여러분의 의견을 기다리겠습니다!
문의하기

기술 세부 정보

O-ring material (process-wetted): Silikon (FDA & USP Class VI geprüft)
O₂가 없는 매체의 잔류 신호: 실내 공기 중 신호의 ≤0.1% | CO2: 실내 공기 중 신호의 ≤0.01%
Perm. temp range (measurement): 0 ... 80 °C
Permissible pressure range (measurement): 0,2 … 6 bar absolut
감지 한계: 1ppb(CO₂가 포함된 액체의 경우 3ppb)
기계적 압력 저항: 최대 절대 압력 12bar
길이: 120 mm
매질과 접촉하는 센서 부품: 스테인리스강 1.4404 (재료 인증서 3.1)
멤브레인 재질: PTFE/Silikon/PTFE, FDA-konform (mit Stahlnetz armiert)
실내 공기 중 신호: 290 … 500 nA
온도 감지기: NTC 22 kΩ
응답 시간(25 °C의 경우)(공기 -> N2): 최대값의 98 % < 90초
정확성: 1% + 1ppb(CO2가 포함된 액체에서는 1% +3ppb)
측정 범위: pO₂ < 1200 mbar
측정 파라미터 : 용존 산소
플러그 헤드: VP (VarioPin)
Measuring Principle: Amperometrisch
Flow dependence: ≤ 5 %
Signal Transmission: analog
Temperature range (stability): –5 ... +121 °C (dampfsterilisierbar/autoklavierbar)
Surface roughness: N 5 (RA < 0,4 μm)
Interior body incl. electrodes: tauschbar (ZU 0568)

다운로드

브로셔

[13395] 브로셔
센서류 - pH/ORP,전도도 또는 용존 산소측정용. 디지털 또는 아날로그

인증서

[14155] Declaration of Compliance 2.1 (DE, EN)
according to EN 10204 | gemäß EN 10204

서비스

Lorem lorem ipsum ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

프로세스 또는 애플리케이션에서 사용

Since steam generator functions are critical to applications and their downtime or replacement is extremely cost intensive, it is important to avoid damage due to wear...

관련 제품

제품 갤러리 건너뛰기

관련 블로그 게시물

Robust WA111 Retractable Fitting Made of Plastic for Highly Corrosive Operating Conditions

The plastic WA111 retractable fitting is a robust and cost-effective solution for corrosive processes and environments. It is equipped with a secure lock function and multiple nozzles for thorough sensor cleaning.

Successful joint project : Knick developed the special Ceramat WA 155 retractable fitting for optical probes from SOPAT

In cooperation with SOPAT, Knick developed a special Ceramat fitting for optical probes for automatic cleaning in fouling processes.

(현장에서) 휴대용으로 사용할 수 있는 고품질의 침적식 피팅

저희 Knick Elektronische Messgeräte GmbH & Co. KG는 pH, 전도도 및 용존 산소의 휴대용 측정에 사용할 수 있는 침적식 피팅 ARD 170을 출시합니다. 제품을 설계 시, 간단하고 유연한 취급이 가능하도록 심혈을 기울였습니다.

방폭 지역에서의 사용을 위한 전기 전도성이 있는 버전의

저희 Knick Elektronische Messgeräte GmbH & Co. KG는 전기 전도성이 있는 버전(EL)의 침적식 피팅 ARD 50 EL 및 ARD 75 EL의 출시를 통해 액상 분석용 피팅의 포트폴리오를 확장했습니다. 이 2개의 산업용 피팅은 모듈식 구조로 되어있어 응용 분야에 맞는 센서를 선택할 수 있는 폭이 넓습니다.

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.