Unical 9000 Electro-pneumatic controller | For automatic cleaning and calibration | Corrosion-proof coating

Description

Unical 9000 Electro-pneumatic controller | For automatic cleaning and calibration | Corrosion-proof coating

Maximum availability of the point of measurement: Cleaning without interrupting the process, even when measuring directly in the pressure tank

  • corrosion-proof (powder-coated stainless steel)
  • consistent enclosure concept for all devices.
  • modular design, adaptable to virtually every measuring task
  • easy assembly and retrofitting
  • tidy hose guiding
  • no entrainment and backmixing due to separate routing of the media
  • low maintenance effort due to innovative pump technology and extremely low consumption of media
  • automatic 2-point calibration
  • time-controlled cleaning and checking
  • cleaning with water and additional cleaning solution
  • reduced maintenance effort due to automatic calibration
  • no interruptions in production for calibration
  • longer sensor life due to short-time measurement and regular cleaning
  • immediate readiness for measurement after production interruption since sensor is safely stored in liquid
  • safety ensured by monitoring of the compressed air and water supply, the probe position and the buffer and cleaning solution level

In combination with the Protos process analysis system and a SensoGate or Ceramat sensor lock-gate, Unical provides the ideal functionality of a complete system for automatic process control of a pH measurement. 

It allows highly accurate measurements to be taken even with difficult process conditions such as high pressure, high temperatures, and high levels of impurities. The system can be installed next to the process, within the hazardous area.

Since the electrode is not removed for calibration, the process can continue uninterrupted. This allows problem-free measurements directly in a pressure vessel or in the main pipe. Elaborate and lockable bypasses are eliminated and accuracy increases.

Low maintenance
Fully automatic sensor calibration at user-defined intervals without interrupting the process. Two buffer solutions are automatically pumped into the calibration chamber. Only the buffer bottles need to be refilled.

Cost-effective
Low-wear and low-maintenance pumps with extremely low consumption of buffer.

Safe and easy measurement even in strongly polluted media
Sensor cleaning and rinsing is performed at user-defined intervals. Cleaning solution and water are automatically pumped into the calibration chamber. Removal and manual cleaning of the sensor are not required.

Distinction between calibration and adjustment
This allows you to check the sensor data in the running process. An adjustment is only carried out when there are preset deviations of the calibration values. Constant displacement of the measured values due to small calibration scatters is omitted.

Modern fieldbus integration
The interfaces to PROFIBUS PA or Foundation Fieldbus allow the Unical system to be integrated directly in a fieldbus network. Of course, also in hazardous areas.

Universal adaptation to retractable fittings
The modular structure of the Unical system allows any retractable fittings to be used. Optimum functionality is achieved with the Ceramat and Sensogate sensor lock-gates.

Clean and safe construction
All features for smooth, safe, and low-maintenance operation are included as standard: water pressure gage and service switch with alert message and feedback of the actual lock-gate position, air filter and water trap. Flooding sensor in the housing with alert message.

여러분의 의견을 기다리겠습니다!
문의하기

기술 세부 정보

보호 등급: IP 65/NEMA 4X
외함: Stainless steel A2, coated
측정 파라미터 : pH/ORP
치수(W x H x D): 약 320 x 400 x 120mm
폭발 방지: 전직 없음

다운로드

Manuals

[14286] Accessories Manual | Zubehöranleitung
ZU 0812 Multiplug Bottom Section Conversion Kit / ZU 1067 Multiplug Middle Section Conversion Kit
Umbausatz ZU 0812 Multistecker-Unterteil / Umbausatz ZU 1067 Multistecker-Mittelteil
Version 02
[17320] 사용 설명서 (매뉴얼)
Unical 9000/Protos II 4400
Version 02
[14145] User Manual
ZU 0741/1 (PTFE, stainless steel (1.4408, 1.4401)
Chemical Pump for Probe Controllers Uniclean 900(X), Unical 9000(X)
Version 04
[14190] User Manual
ZU 0741 (PFA, PVDF, PTFE)
Chemical Pump for Probe Controllers Uniclean 900(X), Unical 9000(X)
Version 03

데이터 시트

[3998] Data sheet
Unical 9000
Product Description | Specifications | Product Range

인증서

[13931] EU Declaration of Conformity (DE, EN, FR)
No. EU230413B | 2023-04-21
Unical 9000-N | Uniclean 900-N

서비스

Lorem lorem ipsum ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

프로세스 또는 애플리케이션에서 사용

Measuring of pH in pre-Scrubber, in neutralization and in lime scrubber within the flue gas desulfurization process in power plants.

관련 블로그 게시물

Sturdy 2-Electrodes Conductivity Sensor SE625 with Coaxial Electrodes made of Titanium

The SE625 ensures reliable and accurate determination of the conductivity of ultrapure water in the semiconductor industry.

Combined pH- and ORP-Sensor SE555X/*-AMSN

Combined pH and ORP measurement in one sensor SE555 saves place and equipment costs for demanding requirements in the chemical industry, the food sector and for hygienic applications.

SE655X 디지털 및 SE656X 디지털 - 방폭 인증을 받은 디지털 전도도 센서

Memosens 프로토콜을 채택한 전도도 센서 SE655X 디지털 및 SE656X 디지털은 이제 방폭 인증을 받은 제품으로 사용할 수 있습니다. 이 센서들은 재질과 설계로 인해 특히 화학, 제지 및 펄프 산업과 산업 폐수 모니터링에 적합합니다.

새 디지털 전도도 센서 SE656N

New toroidal Digital Conductivity Sensor with a large measuring range and consisting of PFA for using in aggressive media

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.