Unical 9000 Electro-pneumatic controller | For automatic cleaning and calibration | Ex | Hygienic Surface

Description

Unical 9000 Electro-pneumatic controller | For automatic cleaning and calibration | Ex | Hygienic Surface

Maximum availability of the point of measurement: Cleaning without interrupting the process, even when measuring directly in the pressure tank

  • hygienic version (polished stainless steel)
  • operation in hazardous locations Zone 1 (all system components)
  • consistent enclosure concept for all devices.
  • modular design, adaptable to virtually every measuring task
  • easy assembly and retrofitting
  • tidy hose guiding
  • no entrainment and backmixing due to separate routing of the media
  • low maintenance effort due to innovative pump technology and extremely low consumption of media
  • automatic 2-point calibration
  • time-controlled cleaning and checking
  • cleaning with water and additional cleaning solution
  • reduced maintenance effort due to automatic calibration
  • no interruptions in production for calibration
  • longer sensor life due to short-time measurement and regular cleaning
  • immediate readiness for measurement after production interruption since sensor is safely stored in liquid
  • safety ensured by monitoring of the compressed air and water supply, the probe position and the buffer and cleaning solution level

In combination with the Protos process analysis system and a SensoGate or Ceramat sensor lock-gate, Unical provides the ideal functionality of a complete system for automatic process control of a pH measurement. 

It allows highly accurate measurements to be taken even with difficult process conditions such as high pressure, high temperatures, and high levels of impurities. The system can be installed next to the process, within the hazardous area.

Since the electrode is not removed for calibration, the process can continue uninterrupted. This allows problem-free measurements directly in a pressure vessel or in the main pipe. Elaborate and lockable bypasses are eliminated and accuracy increases.

Low maintenance
Fully automatic sensor calibration at user-defined intervals without interrupting the process. Two buffer solutions are automatically pumped into the calibration chamber. Only the buffer bottles need to be refilled.

Cost-effective
Low-wear and low-maintenance pumps with extremely low consumption of buffer.

Safe and easy measurement even in strongly polluted media
Sensor cleaning and rinsing is performed at user-defined intervals. Cleaning solution and water are automatically pumped into the calibration chamber. Removal and manual cleaning of the sensor are not required.

Distinction between calibration and adjustment
This allows you to check the sensor data in the running process. An adjustment is only carried out when there are preset deviations of the calibration values. Constant displacement of the measured values due to small calibration scatters is omitted.

Modern fieldbus integration
The interfaces to PROFIBUS PA or Foundation Fieldbus allow the Unical system to be integrated directly in a fieldbus network. Of course, also in hazardous areas.

Universal adaptation to retractable fittings
The modular structure of the Unical system allows any retractable fittings to be used. Optimum functionality is achieved with the Ceramat and Sensogate sensor lock-gates.

Clean and safe construction
All features for smooth, safe, and low-maintenance operation are included as standard: water pressure gage and service switch with alert message and feedback of the actual lock-gate position, air filter and water trap. Flooding sensor in the housing with alert message.

여러분의 의견을 기다리겠습니다!
문의하기

기술 세부 정보

보호 등급: IP 65/NEMA 4X
승인: ATEX, FM, KCs, NEPSI
외함: Stainless steel A2, polished
측정 파라미터 : pH/ORP
치수(W x H x D): 약 320 x 400 x 120mm
폭발 방지: Ex, hazardous area Zone 1

다운로드

Manuals

[14286] Accessories Manual | Zubehöranleitung
ZU 0812 Multiplug Bottom Section Conversion Kit / ZU 1067 Multiplug Middle Section Conversion Kit
Umbausatz ZU 0812 Multistecker-Unterteil / Umbausatz ZU 1067 Multistecker-Mittelteil
Version 02
[17320] 사용 설명서 (매뉴얼)
Unical 9000/Protos II 4400
Version 02
[14145] User Manual
ZU 0741/1 (PTFE, stainless steel (1.4408, 1.4401)
Chemical Pump for Probe Controllers Uniclean 900(X), Unical 9000(X)
Version 04
[14190] User Manual
ZU 0741 (PFA, PVDF, PTFE)
Chemical Pump for Probe Controllers Uniclean 900(X), Unical 9000(X)
Version 03

데이터 시트

[3998] Data sheet
Unical 9000
Product Description | Specifications | Product Range

인증서

[7720] EU Type-Examination Certificate
Unical 9000-X... and Uniclean 900-X...
KEMA 04 ATEX 1036
Issue Number 5 | 2022-07-28
[13926] EU Declaration of Conformity (DE, EN, FR)
No. EU230413A | 2023-04-21
Unical 9000-X | Uniclean 900-X
[18019] Certificate of Conformity (FM-CA)
Unical 9000-X, Uniclean 900-X
Hazardous Location Electrical Equipment per Canadian Requirements
No. FM22CA0056 | 2022-12-08
[18020] IECEx Certificate of Conformity
Types Unical 9000-X… and Uniclean 900-X…
No.: IECEx DEK 22.0022 | 2022-07-28
Issue No. 0
[12576] Certitficate of Conformity (China - Ex NEPSI)
No. GYJ20.1055 | 2020-08-20
Unical 9000 X, Uniclean 900 X
[16945] Korean Safety Certificate
Unical 9000-X
Ex ia [ia Ga] IIC T4 Gb
21-KA4BO-0868 | 2023-03-01
[17571] Certificate of Conformity (FM-US)
Unical 9000-X, Uniclean 900-X
Hazardous Location Electrical Equipment
No.3024483 | 2022-12-08

제어 도면

[16569] Control Drawing
Unical 9000-X… / Uniclean 900-X…
Zeichnungsnummer 207.001-066 page 1a-1b rev.0
ATEX, IECEx
[16563] Control Drawing
Unical 9000-X… / Uniclean 900-X…
Zeichnungsnummer 207.001-066 page 2a-2b rev.0
cFMus

서비스

Lorem lorem ipsum ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

프로세스 또는 애플리케이션에서 사용

Measuring of pH in pre-Scrubber, in neutralization and in lime scrubber within the flue gas desulfurization process in power plants.

관련 블로그 게시물

Robust WA111 Retractable Fitting Made of Plastic for Highly Corrosive Operating Conditions

The plastic WA111 retractable fitting is a robust and cost-effective solution for corrosive processes and environments. It is equipped with a secure lock function and multiple nozzles for thorough sensor cleaning.

Successful joint project : Knick developed the special Ceramat WA 155 retractable fitting for optical probes from SOPAT

In cooperation with SOPAT, Knick developed a special Ceramat fitting for optical probes for automatic cleaning in fouling processes.

(현장에서) 휴대용으로 사용할 수 있는 고품질의 침적식 피팅

저희 Knick Elektronische Messgeräte GmbH & Co. KG는 pH, 전도도 및 용존 산소의 휴대용 측정에 사용할 수 있는 침적식 피팅 ARD 170을 출시합니다. 제품을 설계 시, 간단하고 유연한 취급이 가능하도록 심혈을 기울였습니다.

방폭 지역에서의 사용을 위한 전기 전도성이 있는 버전의

저희 Knick Elektronische Messgeräte GmbH & Co. KG는 전기 전도성이 있는 버전(EL)의 침적식 피팅 ARD 50 EL 및 ARD 75 EL의 출시를 통해 액상 분석용 피팅의 포트폴리오를 확장했습니다. 이 2개의 산업용 피팅은 모듈식 구조로 되어있어 응용 분야에 맞는 센서를 선택할 수 있는 폭이 넓습니다.

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.