跳到主要内容 跳到搜索 跳到主导航

A20230 Sensor Transmitter | Input potentiometers and resistors | For safety circuits up to SIL3

Description

A20230 Sensor Transmitter | Input potentiometers and resistors | For safety circuits up to SIL3

The transmitter for potentiometers for position determination, path measurement or setpoint specification in a 6 mm housing.

  • Universal usability
    with potentiometers, resistive sensors, remote resistance transducers and similar sensors
  • Intuitive configuration
    of basic parameters – easy, without tools, using 4 rotary and 8 DIP switches
  • Calibrated range selection
    without complicated trimming
  • Convenient adjustment
    Start and end points are directly adjusted “at the push of a button“ using the teach-in function
  • Protective separation
    according to EN 61140 – protection of the maintenance staff and downstream devices against excessively high voltages up to 300 V AC/DC
  • High accuracy
    with innovative switching concept
  • Minimum space requirement
    in the enclosure – only 6 mm wide modular housing – more transmitters per meter of mounting rail
  • Low-cost assembly
    quick mounting, convenient connection of power supply via DIN rail bus connectors
  • 5-year warranty

The Task
In many fields of industry the positions of actuators or setpoint devices, for example, must be measured accurately. In many cases they are used as a reference input for controllers or monitoring systems, safety shutdown systems, or for similar critical tasks. As a rule, high demands are placed on function, accuracy, flexibility, and electrical safety. Rotary motion can be measured with potentiometers configured as angle sensors, ranslational motion with linear potentiometers as path sensors. These and other sensors provide a raw signal which is prepared, scaled and converted into a standard signal for further processing using a resistance transmitter.

The Problem
Commercial position sensors have individual characteristics, which requires tedious and time-consuming adjustment of the respective resistance transmitter using  otentiometers. Furthermore, resistance transmitters up to now had a very wide modular housing and therefore occupied a large amount of space in the enclosure. For world-wide applications, several versions with different supply voltages were often used.

The Solution
The universal A20230 resistance transmitters provide connection possibilities for all standard potentiometers for angle, path or position detection up to 50 kohms. They can be flexibly adapted to the respective measuring task using DIP and rotary encoder switches or via a “teach-in function“. 3-port isolation with protective separation up to 300 V AC/DC according to EN 61140 ensures optimum protection of personnel and equipment as well as unaltered transmission of measuring signals. The A20230 offer maximum performance in the smallest of spaces. Adjusting the start and end value to the individual position sensor is particularly  convenient using the “teach-in function“ – just at the push of a button on the front of the device. Sensors with known characteristics can be very easily calibrated using four rotary encoder switches and eight DIP switches. Special measuring tasks can be solved with SensoTrans devices which Knick configures according to individual specifications. Fixed-range devices without switch are used, for example, when manipulations or mix-ups must be precluded.

Knick Products Comply With UL - What Does That Mean?

There are different assessments and approaches to reach an adequate level of safety. Manufacturers are typically on the “safe” side, if they comply with recognized standards.

我们期待您的来信
联系我们

技术细节

产品类别: 测量变送器
产品系列: ProLine
截止频率: < 1 kHz
最小工作电压: 50 V, 300 V
最小测试电压: 2,5 kV, 510 V
电源: 24 V DC
设备类型: 电阻测量变送器
防爆认证类别: CSA, UL
输入: 电阻 / 电位计
输出: 0 … 10 V, 0 … 20 mA, 4 … 20 mA
误差级别: 0.1 %, < 0.5 %
结构型式: 6 mm 模块化外壳

下载

Manuals

[294] User Manual (DE, EN, FR, BR)
A20230 P0/
Version 02
[13390] User Manual (DE, EN, FR, ES)
ZU 0677 (Power terminal block)
Version 03

数据手册

[285] 数据手册
A20230
产品描述 | 规格 | 产品范围

证书

[11418] Certificate of Compliance (UL)
No. 20181015-E220033 | 2018-OCTOBER-15
POWER CIRCUIT AND MOTOR-MOUNTED APPARATUS
P32*00P0/**, A202*0P0..., BL520
[11256] CB Test Certificate
No. DE 2-036775 | 2022-10-11
P32000, P32100, P32200, P32300, A20210, A20220, A20230
[13789] EU Declaration of Conformity (DE, EN, FR)
A20210P0, P32100P0, A20220P0, P32200P0, A20230P0, P32300P0, P32000P0
No. EU231123A | 2023-11-23

Software

[11876] Knick Produktmakros (.pdf)
ePLAN Electric P8
[12154] Software (.zip)
ePLAN P8 Produktmakros

我们的服务

Lorem lorem ipsum ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

在工艺或应用中使用

高压隔离放大器和变送器,用于采集和转换电流、电压、温度、转速、应变和电阻信号。
Knick 的电气测量技术为信号采集和转换以及电流、电压等测量提供多种解决方案。

相关的博客文章

Robust WA111 Retractable Fitting Made of Plastic for Highly Corrosive Operating Conditions

The plastic WA111 retractable fitting is a robust and cost-effective solution for corrosive processes and environments. It is equipped with a secure lock function and multiple nozzles for thorough sensor cleaning.

成功的聯合專案: 尼克公司開發了特殊的塞拉馬特 WA 155 可伸縮配件, 用於 SOPAT 的光學探頭

污染過程中光學探頭的自動清潔:尼克斯和 SOPAT 與 Ceramat 客戶應用的聯合專案

适合移动应用场景的高品质浸入式连接件

Knick Elektronische Messgeräte GmbH & Co. KG 公司向市场上推出的 ARD 170 是一款高品质浸入式连接件,用于移动式测量 pH 值、电导率和溶解氧。在进行结构设计时,特别注意简单灵活的操作方式。

导电版模块化浸入式连接件

Knick Elektronische Messgeräte GmbH & Co. KG 公司借助浸入式连接件 ARD 50 EL 和 ARD 75 EL 在自己的液体分析连接件产品组合中增加了导电 (EL) 版。这两种工业连接件具有模块化结构,可以广泛选择各种专用传感器。

How to get the sensor into the process