A20400 Isolated Standard Signal Conditioner | Input 0(4) … 20 mA | Isolation up to 600 V | Load stop function

Description

A20400 Isolated Standard Signal Conditioner | Input 0(4) … 20 mA | Isolation up to 600 V | Load stop function

The first decoupled passive isolator with load stop function to provide protective separation of 0(4) ... 20 mA standard signals.

  • Extremely compact design
    up to 320 channels per meter
  • 1- and 2-channel versions
    cheap and flexible for a wide range of applications
  • Galvanic isolation
    between the input and output protection against incorrect measurements or damage to the equipment due to parasitic voltages
  • Protective separation up to 300 V AC/DC according to EN 61140
    to protect personnel and equipment
  • Load stop function prevents feedback
    e.g. in the case of an open output circuit
  • No power supply required
    Cost saving due to lower wiring effort no mains interference, no unnecessary self-heating and therefore maximum component service life
  • High accuracy
    No distortion of the measurement signal
  • Maximum reliability
    No repair and failure costs
  • International use
    UL / CSA approvals
  • 5-year warranty

Thanks to an extremely high packing density of up to 320 channels per meter of mounting rail and outstanding technical properties such as protective separation, these isolators leave the competition in the dust – even when it comes to the price-performance ratio!

The A20400 draws its power as a voltage drop directly from the measurement signal without falsifying it. There are no costs for a power supply and wiring. The A20400 has virtually no self-heating that would cause the electronic components to age faster. Together with a patented circuit design, this means maximum reliability. The consequence of this extraordinary long service life: 5-year warranty!

我们期待您的来信
联系我们

技术细节

产品类别: 通用隔离器 / 标准信号隔离器
产品系列: ProLine
截止频率: < 1 kHz
最小工作电压: 50 V, 300 V
最小测试电压: 2,5 kV, 510 V
电源: 环路供电
设备类型: 环路供电标准信号隔离器,无辅助电源
防爆认证类别: CSA, DNV, UL
输入: (±)20 mA, 4 … 20 mA
输出: 0 … 20 mA, 4 … 20 mA
误差级别: 0.1 %, < 0.5 %
结构型式: 6 mm 模块化外壳

下载

Manuals

[861] User Manual (DE, EN)
A204**
Version 05

小册子

[14160] 手册
产品总览 接口技术

数据手册

[854] 数据表
A20400
产品描述 | 规格 | 产品范围

证书

Certificate of Compliance (UL)
No. 20181015-E220033; 2018-10-15
POWER CIRCUIT AND MOTOR-MOUNTED APPARATUS
A204** and BL541
[12611] DNV•GL Type Approval Certificate
No. TAA00000AX | 2021-04-06
Revision No: 2
A204**P0

Software

[11876] Knick Produktmakros (.pdf)
ePLAN Electric P8
[12154] Software (.zip)
ePLAN P8 Produktmakros

我们的服务

Lorem lorem ipsum ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

在工艺或应用中使用

高压隔离放大器和变送器,用于采集和转换电流、电压、温度、转速、应变和电阻信号。
长期稳定的高压隔离放大器、变送器和信号倍增器,适用于要求苛刻的应用

相关的博客文章

Robust WA111 Retractable Fitting Made of Plastic for Highly Corrosive Operating Conditions

The plastic WA111 retractable fitting is a robust and cost-effective solution for corrosive processes and environments. It is equipped with a secure lock function and multiple nozzles for thorough sensor cleaning.

成功的聯合專案: 尼克公司開發了特殊的塞拉馬特 WA 155 可伸縮配件, 用於 SOPAT 的光學探頭

污染過程中光學探頭的自動清潔:尼克斯和 SOPAT 與 Ceramat 客戶應用的聯合專案

适合移动应用场景的高品质浸入式连接件

Knick Elektronische Messgeräte GmbH & Co. KG 公司向市场上推出的 ARD 170 是一款高品质浸入式连接件,用于移动式测量 pH 值、电导率和溶解氧。在进行结构设计时,特别注意简单灵活的操作方式。

导电版模块化浸入式连接件

Knick Elektronische Messgeräte GmbH & Co. KG 公司借助浸入式连接件 ARD 50 EL 和 ARD 75 EL 在自己的液体分析连接件产品组合中增加了导电 (EL) 版。这两种工业连接件具有模块化结构,可以广泛选择各种专用传感器。

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.