跳到主要内容 跳到搜索 跳到主导航

SE554_default

Description

SE554_default

Low-maintenance sensor for demanding process applications in the chemical industry, digital, with Memosens technology

  • Höhere Betriebstemperatur
  • Erweiterte Ex-Zulassung
  • Diagnose Belastungsmatrix u. Statistik

 Bisheriger Text:

  • Simultaneous measurement of pH and ORP
  • Perfect galvanic isolation thanks to Memosens technology
  • No influence of humidity in the connector
  • Precalibration in the lab
  • Digital data transfer
  • Integrated sensor diagnostics
  • Low maintenance, no refilling of electrolyte
  • Integrated temperature detector
  • Open junctions, no blocking

The special design provides high accuracy, stability, speed, and a long life cycle. Through 2 open junctions, the reference system is in direct contact with the measured medium. There is hardly any risk of contamination or blocking of the junction. The high content and special distribution of potassium chloride in the polymer reduces measurement disturbances which could be caused by liquid junction potentials.

Applications
Measurement in media of extremely high ionic strength, salt brines, strongly oxidizing media, acidic and alkaline media

我们期待您的来信
联系我们

技术细节

插接头: Memosens
是否防爆: Ex
测量参数: pH, pH/ORP, ORP
长度: 120 mm

下载

Manuals

[13184] 操作说明书
SE554 pH 传感器,pH/氧化还原传感器
Version 04
[14165] User Manual | Betriebsanleitung
ZU1054 Sensor Protection | Sensorschutz
Version 01
[16286] User Manual (DE, EN, KO)
Memosens Cable CA/MS
Version 09

小册子

[13395] 宣传册
传感器 - 适用于测量pH/氧化还原值、电导率和氧。数字式与模拟式。

数据手册

[12872] 数据表
SE554X/*-AMSN Memosens pH/氧化还原传感器
产品描述 | 规格 | 产品范围

证书

[18254] Manufacurer's Declaration
Confirmation of the Compatibility of Digital Sensors from Our Company
Identifier: -B1
[12781] EU Declaration of Conformity (DE, EN, FR)
No. EU210706D | 2021-07-06
Memosens Measuring Cable Type CA/MS-...X.., CA/MS-...X..-L
[18270] Certitficate of Conformity (China - Ex NEPSI)
Cert No. GYJ24.1052X
SE5aa X/b-*MS*-B1
2024-04-03
[18286] Certificate of Conformity (FM)
No. FM23CA0070X | 2024-04-16 | Canada
Memosens Sensors | Types SE 5**X/*-*MS*-B1 (pH/ORP)
[14155] Declaration of Compliance 2.1 (DE, EN)
according to EN 10204 | gemäß EN 10204
O-Ringe aus EPDM oder Silikon | O-rings made of EPDM or Silicone
[12826] EU-Type Examination Certificate (DEKRA)
Nr. BVS 16 ATEX E 037 X | 2024-02-20
Memosens-Ex-Sensors
[18294] IECEx Certificate of Conformity
No. IECEX DEK 22.0019X
Issue No. 1 | 2025-01-09
Memosens, types SE5**X/*−*MS*−B1, SE605*-X*MS****… and SE625-X*MS*******…
[18262] EU Declaration of Conformity (DE, EN, FR)
Sensors Types SE5**X/*-*MS*-*B1
EU230912A | 2025-04-30
[18278] Certificate of Conformity (FM)
No. FM23US0105X | 2024-04-16 | USA
Memosens Sensors | Types SE 5**X/*-*MS*-B1 (pH/ORP)

Safety guides

[11046] Material Safety Data Sheet
CaliMat buffer solution pH 9,00
[11044] Material Safety Data Sheet
CaliMat buffer solution pH 12,00
[11049] Material Safety Data Sheet
CaliMat buffer solution pH 2,00
[11045] Material Safety Data Sheet
CaliMat buffer solution pH 7,00
[11048] Material Safety Data Sheet
CaliMat buffer solution pH 4,00

控制图纸

[18302] Control Drawing
Memosens pH Sensors Type SE5**X/*−*MS*−B1
Zeichnungsnummer 213.215-066 page 1b rev.1
ATEX, IECEx

我们的服务

Lorem lorem ipsum ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

在工艺或应用中使用

Measuring of pH in pre-Scrubber, in neutralization and in lime scrubber within the flue gas desulfurization process in power plants.
The taste and quality of beer greatly depend on the quality of the water used to brew it. pH and conductivity measurements determine its quality. Globalization is putting massive competitive pressure…
Recording raw water values plays a key role in the overall process of drinking water treatment. Measures for neutralizing extreme pH values or oxidation-reduction potentials are not only taken in the spirit of health compatibility, but also…
Depending on the sector, industrial wastewater is polluted by heavy metals, grease, oil, alkaline substances or, as in the paper and soap sectors, organic substances that can only be neutralized or separated with great effort.

相关的博客文章

P45000 SIL 2 / SIL 3: Voltage measurements in applications with functional safety

P45000 SIL 2 / SIL 3: Voltage measurements in applications with functional safety

ACHEMA 2024 Review

ACHEMA 2024 Review

Uniclean 700 Series - Modular control system for automated sensor cleaning

With the Uniclean 700 series, Knick is introducing a modular control system, that can be installed very quickly and cost-effectively as a flexible entry-level solution for automated sensor cleaning.

Knick Austria - direct customer contact in Austria from 2024

Reorganization of sales in Austria and new contacts in the field of process analytics and interface technology