Skip to main content Skip to search Skip to main navigation

Uniclean 900 Electro-pneumatic controller | For automatic cleaning | Hygienic Surface

Description

Uniclean 900 Electro-pneumatic controller | For automatic cleaning | Hygienic Surface

The electro-pneumatic controller for fully automated pH measurement and cleaning

  • hygienic version (polished stainless steel)
  • consistent enclosure concept for all devices
  • modular design, adaptable to virtually every measuring task
  • easy assembly and retrofitting
  • low maintenance effort due to innovative pump technology and extremely low consumption of media
  • time-controlled cleaning
  • cleaning with water and additional cleaning solution
  • reduced maintenance effort due to automatic cleaning
  • no disruption of production for cleaning the sensor
  • longer sensor life due to short-time measurement and regular cleaning
  • immediate readiness for measurement after production interruption since sensor is safely stored in liquid
  • safety ensured by monitoring of the compressed air and water supply, the probe position and the cleaning solution level

In combination with the Protos process analysis system and a SensoGate or Ceramat sensor lock-gate, Uniclean provides the ideal functionality of a complete system for automatic process control of a pH measurement.

Maximum availability of the point of measurement: Cleaning without disrupting the process, even when measuring directly in the pressure vessel.

Since the sensor is not removed for cleaning, the process can continue uninterrupted. This allows problem-free measurements in a pressure tank or in the main pipe. Elaborate and lockable bypasses are eliminated and accuracy increases.

Low maintenance
Fully automatic sensor cleaning with water or special cleaning solution in user-defined intervals without interrupting the process. The cleaning solution is automatically pumped into the cleaning chamber. Only the containers need to be refilled.

Cost-effective
Low-wear and low-maintenance pumps with extremely low consumption of cleaning agent.

Long sensor life also in critical processes
When measuring in aggressive media or at high process temperatures, the sensor rests in the cleaning chamber and is only briefly moved into the process for measurement. The cleaning chamber may be filled with water. This method increases the sensor life significantly.

Safe and easy measurement even in strongly polluted media
Sensor cleaning and rinsing is performed at user-defined intervals. Cleaning solution and water are automatically pumped into the rinsing chamber. Dismantling and manual cleaning of the sensor are omitted.

Modern fieldbus integration
The interfaces to PROFIBUS PA or Foundation Fieldbus allow the Uniclean system to be integrated directly in a fieldbus network. Naturally also in hazardous locations.

Universal adaptation to retractable fittings
The modular structure of the Uniclean system allows any retractable fittings to be used. Optimum functionality is achieved with the Ceramat and SensoGate sensor lock-gates.

Highly accurate measurements
The Uniclean 900 system allows highly accurate measurements to be taken even under difficult process conditions such as high pressure, high temperatures, and high levels of impurities. The device can be installed next to the process, within the hazardous area. Control is via the Protos 4400 measuring system or directly via a PLC.

Clean and safe construction
All features for smooth, safe, and low-maintenance operation are included as standard: Water pressure gauge, air filter and water trap, flooding sensor in the housing with alert message.

我们期待您的来信
联系我们

技术细节

外壳: Stainless steel A2, polished
是否防爆: 非 Ex
电源: 15 ... 30 V / 20 mA, 通过 Protos 模块 PHU 3400(X)-110(6.8 V (±10 %)/15 mA)供电
防护等级: IP 65/NEMA 4X

下载

Manuals

[14286] Accessories Manual | Zubehöranleitung
ZU 0812 Multiplug Bottom Section Conversion Kit / ZU 1067 Multiplug Middle Section Conversion Kit
Umbausatz ZU 0812 Multistecker-Unterteil / Umbausatz ZU 1067 Multistecker-Mittelteil
Version 02
[14145] User Manual
ZU 0741/1 (PTFE, stainless steel (1.4408, 1.4401)
Chemical Pump for Probe Controllers Uniclean 900(X), Unical 9000(X)
Version 04
[14190] User Manual
ZU 0741 (PFA, PVDF, PTFE)
Chemical Pump for Probe Controllers Uniclean 900(X), Unical 9000(X)
Version 03

数据手册

[3975] Data sheet
Uniclean 900
Product Description | Specifications | Product Range

证书

[13931] EU Declaration of Conformity (DE, EN, FR)
No. EU230413B | 2023-04-21
Unical 9000-N | Uniclean 900-N

我们的服务

Lorem lorem ipsum ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

在工艺或应用中使用

Measuring of pH in pre-Scrubber, in neutralization and in lime scrubber within the flue gas desulfurization process in power plants.
High quality requirements are placed on raw milk, and online monitoring of truck unloading procedure at the dairy prevents inferior quality (sour milk) from spoiling the entire stock of the storage tank.

相关的博客文章

pH and conductivity measurement in vaccine production

Pharmaceutical contract manufacturer relies on Knick's transmitters for modular production plants for Covid-19 vaccines.

采用 Profinet 技术的新型 Stratos Multi E461N 变送器

新型 Stratos Multi E461N 多参数变送器的 Profinet 接口可实现从现场层直至常见过程控制系统的全程过程变量的通信与预测性维护。

Stratos Multi E401X - 用于易爆区域的多参数变送器

Knick 成熟的分析测量仪器家族中,现又全新增添了 Stratos Multi,可用于易爆区域。

The Big Three of the Process Industry: HART, FF, Profibus

Our Knick multi-parameter analyzers are now available with Profibus and FF interfaces. Even for hazardous areas.