Passer au contenu principal Passer à la recherche Passer à la navigation principale

SE655 Toroidal Conductivity Sensor | Memosens | 3 m Fixed cable | PEEK | High chemical resistance

Description

SE655 Toroidal Conductivity Sensor | Memosens | 3 m Fixed cable | PEEK | High chemical resistance

Universal and precise conductivity sensor with high chemical resistance. Digital with Memosens protocol.

  • Process-wetted material: PEEK
  • Sturdy design
  • Resistant to contamination and fouling
  • Range of six decades
  • Steam sterilizable and CIP capable
  • Inductive measuring principle, full galvanic isolation of sensor coils from process medium 
  • Digital with Memosens protocol

The SE655N digital toroidal conductivity sensor is a sturdy and corrosion-resistant sensor that, thanks to its high chemical resistance, is particularly suitable for applications in the chemical industry.

A combination of a large sensor opening and dirt-repellent material prevents blockages and deposits in media with a high pollution degree. The inductive measuring principle enables full galvanic isolation of the measurement from the medium.

The sensor is an all-rounder, suitable for a multitude of applications with a range covering six decades. Equipped with Memosens protocol as a digital version, it offers considerable process and data security, and ensures reliable data recording. Also for hazardous areas (SE655X-GEFTT0AM).

Applications
Concentration measurement of acids and bases, online quality monitoring of chemical products in tanks and pipes, phase separation of product mixtures, paper manufacturing (high fiber concentration), heavily soiled media and wastewater, fouling and oil-contaminated media, brine, regeneration of ion exchangers.

 

 

 

Nous attendons avec impatience votre réponse!
Nous Contacter

Détails techniques

Différence de mesure: ± (0,005 mS/cm + 0,5 % de la valeur mesurée) | (-20 ... +100 °C), ± (0,010 mS/cm + 0,5 % de la valeur mesurée) | (> 100 °C)
Facteur de cellule: 1,98 /cm (≥ 30 mm de distance de la paroi)
Paramètres de mesure: conductivité (induktive)
Plage de mesure: 0 … 2000 µS/cm
Principe de mesure: Inductif
Protection: IP 68 (sonde montée avec joint d'origine / EN 60529)
Protection contre les explosions: pas d'Ex
Raccordement process: G 3/4“ (écrou surplat 36 et joint FKM (Viton) inclus dans le contenu)
Résolution: 0,002 µS/cm
Sonde de température: Pt1000 (Klasse A nach IEC 60751)
Température ambiante: –20 ... +60 °C
Température de stockage: –20 ... 80 °C
Transmission du signal: Memosens-Protokoll
Relative process pressure: 0 ... 20 bar (cf. diagramme pression-température)
Fixed cables with ferrules: 3 m
Temp. response time t90: env. 7 min

Téléchargements

Manuals

[13989] User Manual
SE655(N/X-*) / SE656(N/X-*)
Digital Toroidal Conductivity Sensor

Brochures

[13395] Brochure
Sondes - Pour la mesure du pH/redox, de la conductivité et de l’oxygène. Numérique et analogique.

Fiches techniques

[16521] Fiche technique
Sonde de conductivité inductive SE655(N/X)
Description du produit | Caractéristiques techniques | Gamme de produits

Certificats

[14511] EU Declaration of Conformity (DE, EN, FR)
No. EU240402B | 2024-04-02
Digital Sensors, non Ex

Notre service

Lorem lorem ipsum ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

Utilisé dans les processus ou les applications

The taste and quality of beer greatly depend on the quality of the water used to brew it. pH and conductivity measurements determine its quality. Globalization is putting massive competitive pressure…
Biological wastewater treatment plants produce toxic sludge that must undergo a phosphorous recovery process. The hazardous gases released during ...
Many measuring points in pulp production are positioned in environments where the presence of technical personnel must be restricted to a minimum. Due to the aggressive process media with high solids...

Produits apparentés

Ignorer la galerie de produits

Articles de blog pertinents

Robust WA111 Retractable Fitting Made of Plastic for Highly Corrosive Operating Conditions

The plastic WA111 retractable fitting is a robust and cost-effective solution for corrosive processes and environments. It is equipped with a secure lock function and multiple nozzles for thorough sensor cleaning.

Coopération réussie : Knick a développé un support rétractable spécial Ceramat WA 155 pour les sondes optiques de SOPAT.

Nettoyage automatique des sondes optiques dans les processus d'encrassement : Un projet commun de Knick et SOPAT pour une application client avec Ceramat.

Canne d’immersion haute qualité pour applications mobiles

Avec l’ARD 170, Knick propose une canne d’immersion haute qualité pour mesures mobiles du pH, de la conductivité et de l’oxygène dissous. Les développeurs ont accordé une attention particulière à la simplicité et la flexibilité d’utilisation.

Canne d'immersion modulaire en version électriquement conductrice

Avec ses cannes d'immersion ARD 50 EL et ARD 75 EL, Knick complète de deux versions électriquement conductrices (EL) son portefeuille de cannes d’analyse de liquides. Les modulaires permettent l’utilisation de sondes spécifiques aux applications.

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.