SE655 Toroidal Conductivity Sensor | Fixed cable | PEEK | High chemical resistance

Description

SE655 Toroidal Conductivity Sensor | Fixed cable | PEEK | High chemical resistance

Universal and precise sensor with high chemical resistance over a very large measuring range, for heavily polluted media.

  • Sturdy design
  • Extremely large measuring range due to inductive measuring principle
  • Insensitive to contamination
  • No process-wetted electrodes
  • High chemical resistance (PEEK)
  • Steam-sterilizable
  • CIP-capable

Corrosion-resistant toroidal sensor for measuring pure water up to maximum conductivities. Smooth, easy-to-clean design. High accuracy due to electrodeless measurement. Low risk of contamination because of large sensor opening. Also for hazardous locations (SE655X).

Applications
Concentration measurement of acid and alkaline solutions, heavily polluted media, coating-forming and oil-containing media, salt spring, heavily polluted wastewaters, cooling water blowdown, concentrate monitoring, regeneration of ion exchangers

 

여러분의 의견을 기다리겠습니다!
문의하기

기술 세부 정보

Pressure: 0 … 20 bar
공정 체결: G 3/4“ (Mutter SW 36 und FKM-(Viton-)Dichtung im Lieferumfang)
보호 등급: IP 68 (when mounted)
셀 상수: 약 2/cm(벽면 거리 ≥ 30mm)
온도: -20 … 125 °C
온도 감지기: Pt100 (Klasse A)
재질: PEEK
측정 범위: 0,002 … 2000 mS/cm
측정 파라미터 : 전도도(유도식)
케이블: 5 m 고정식 케이블
폭발 방지: 전직 없음
Measuring Principle: Induktiv
Signal Transmission: analog

다운로드

Manuals

[2684] User Manual
SE655(X) / SE656(X) Toroidal Conductivity Sensors
Version 07

브로셔

[13395] 브로셔
센서류 - pH/ORP,전도도 또는 용존 산소측정용. 디지털 또는 아날로그

데이터 시트

[16722] Data sheet
SE655(X) Toroidal Conductivity Sensor
Product Description | Specifications | Product Range

인증서

[14516] EU Declaration of Conformity (DE, EN, FR)
Analog Sensors, non Ex
No. EU250213A | 2025-02-13

서비스

Lorem lorem ipsum ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

프로세스 또는 애플리케이션에서 사용

The taste and quality of beer greatly depend on the quality of the water used to brew it. pH and conductivity measurements determine its quality. Globalization is putting massive competitive pressure…
Biological wastewater treatment plants produce toxic sludge that must undergo a phosphorous recovery process. The hazardous gases released during ...
Many measuring points in pulp production are positioned in environments where the presence of technical personnel must be restricted to a minimum. Due to the aggressive process media with high solids...

관련 제품

제품 갤러리 건너뛰기

관련 블로그 게시물

Robust WA111 Retractable Fitting Made of Plastic for Highly Corrosive Operating Conditions

The plastic WA111 retractable fitting is a robust and cost-effective solution for corrosive processes and environments. It is equipped with a secure lock function and multiple nozzles for thorough sensor cleaning.

Successful joint project : Knick developed the special Ceramat WA 155 retractable fitting for optical probes from SOPAT

In cooperation with SOPAT, Knick developed a special Ceramat fitting for optical probes for automatic cleaning in fouling processes.

(현장에서) 휴대용으로 사용할 수 있는 고품질의 침적식 피팅

저희 Knick Elektronische Messgeräte GmbH & Co. KG는 pH, 전도도 및 용존 산소의 휴대용 측정에 사용할 수 있는 침적식 피팅 ARD 170을 출시합니다. 제품을 설계 시, 간단하고 유연한 취급이 가능하도록 심혈을 기울였습니다.

방폭 지역에서의 사용을 위한 전기 전도성이 있는 버전의

저희 Knick Elektronische Messgeräte GmbH & Co. KG는 전기 전도성이 있는 버전(EL)의 침적식 피팅 ARD 50 EL 및 ARD 75 EL의 출시를 통해 액상 분석용 피팅의 포트폴리오를 확장했습니다. 이 2개의 산업용 피팅은 모듈식 구조로 되어있어 응용 분야에 맞는 센서를 선택할 수 있는 폭이 넓습니다.

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.