Stratos Pro A221N Multiparameter Transmitter | Memosens/Analog Sensors | Profibus

Description

Stratos Pro A221N Multiparameter Transmitter | Memosens/Analog Sensors | Profibus

2-wire analyzer (PROFIBUS DP/PA)

  • Intuitive operation with color-coded user guidance
  • IP 66/67, NEMA 4X protection
  • Automatic sensor identification
  • Sensor diagnostic with wear indication, remaining lifetime, CIP/SIP counter and adaptive calibration timer
  • High-contrast widescreen display with colored backlighting
  • Protective pane made of safety glass
  • One analog input (4 ... 20 mA) e.g. for external pressure compensation
  • Two parameter sets
  • Two digital inputs: 
    • External HOLD activation
    • External switching between parameter set
  • Logbook (200 entries)
Outstanding properties
A number of outstanding technological properties make the Stratos Pro series the new benchmark for 2-wire analyzers. Colored screen backlighting has been implemented for the first time in this device class, with the lowest possible power consumption.
 
Wide Range of Functions
2 digital inputs are provided, as well as an analog input plus a second current output for another measured value. 

여러분의 의견을 기다리겠습니다!
문의하기

기술 세부 정보

2선식 또는 4선식: 2선
permanently installed / portable: permanently installed
디스플레이: 컬러 백라이트가 있는 LC 디스플레이
센서 연결: Memosens | 아날로그
외함: Molded enclosure, PBT/PC, glass-reinforced
전류 출력: mA 출력 없음
전원 공급장치: 24 V AC/DC
제품 라인: Stratos, Stratos Pro
채널: 1 채널
측정 파라미터 : pH, pH/ORP, 다중 매개변수, 용존 산소, ORP, 전도도
통신(출력, 디지털): PROFIBUS
폭발 방지: 전직 없음

다운로드

Manuals

[12606] 사용 설명서
PROFIBUS DP/PA
Stratos Evo A451N | Stratos Pro A221 (N/X)
Version 02

브로셔

[14695] Brochure
Stratos Pro
2-wire analyzers for pH/ORP, conductivity or oxygen
[13209] 브로셔
Memosens@Knick

데이터 시트

[16180] 데이터 시트
Stratos Pro A201
제품 설명 | 명세서 | 제품 범위

인증서

[12917] Quality Control Certificate
Device Settings for Customer-Specific Buffer Solutions
Version 01
[12455] EU Declaration of Conformity (DE, EN, FR)
Stratos Pro PA A221N, Stratos Pro FF A231N
Document No. EU220121F | 2022-01-21

Software

[16168] GSD
Stratos Pro A221 Multi (PA)
Device Revision 01
[18054] Software
KnUT (Knick Update Tool)
[17577] SOFTWARE
FDI
Stratos Profibus PA A221 Multi
Device Revision 01
[13601] DTM (Pactware)
Stratos Profibus PA A221 Multi
Device Revision 01
[13606] EDD (PDM)
Stratos Profibus PA A221 Multi
Device Revision 01

서비스

Lorem lorem ipsum ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

프로세스 또는 애플리케이션에서 사용

Cooling towers are used in a range of industrial sectors for diverting process heat from cooling circuits. Mineral deposits and corrosion reduce efficiency and lead to the premature wear of system components…

관련 제품

제품 갤러리 건너뛰기

관련 블로그 게시물

Sturdy 2-Electrodes Conductivity Sensor SE625 with Coaxial Electrodes made of Titanium

The SE625 ensures reliable and accurate determination of the conductivity of ultrapure water in the semiconductor industry.

Combined pH- and ORP-Sensor SE555X/*-AMSN

Combined pH and ORP measurement in one sensor SE555 saves place and equipment costs for demanding requirements in the chemical industry, the food sector and for hygienic applications.

SE655X 디지털 및 SE656X 디지털 - 방폭 인증을 받은 디지털 전도도 센서

Memosens 프로토콜을 채택한 전도도 센서 SE655X 디지털 및 SE656X 디지털은 이제 방폭 인증을 받은 제품으로 사용할 수 있습니다. 이 센서들은 재질과 설계로 인해 특히 화학, 제지 및 펄프 산업과 산업 폐수 모니터링에 적합합니다.

새 디지털 전도도 센서 SE656N

New toroidal Digital Conductivity Sensor with a large measuring range and consisting of PFA for using in aggressive media

How to get the sensor into the process