메인 콘텐츠로 건너뛰기 검색으로 건너뛰기 메인 메뉴로 건너뛰기

Stratos Pro A201 CONDI Inductive Conductivity Transmitter | Analog Sensors | Ex Zone 2 | HART | 2x 4 ... 20 mA Outputs

Description

Stratos Pro A201 CONDI Inductive Conductivity Transmitter | Analog Sensors | Ex Zone 2 | HART | 2x 4 ... 20 mA Outputs

2-wire analyzer for conductivity measurement

  • Operation in hazardous areas
  • Two current outputs
  • Digital communication: HART 
  • Intuitive operation with color-coded user guidance
  • IP 66/67, NEMA 4X protection
  • Automatic sensor identification
  • Sensor diagnostic with wear indication, remaining lifetime, CIP/SIP counter and adaptive calibration timer
  • High-contrast widescreen display with colored backlighting
  • Protective pane made of safety glass
  • One analog input (4 ... 20 mA) e.g. for external pressure compensation
  • Two parameter sets
  • Two digital inputs: 
    • External HOLD activation
    • External switching between parameter set
  • Logbook (200 entries)
Outstanding properties
A number of outstanding technological properties make the Stratos Pro series the new benchmark for 2-wire analyzers. Colored screen backlighting has been implemented for the first time in this device class, with the lowest possible power consumption.
 
Wide Range of Functions
2 digital inputs are provided, as well as an analog input plus a second current output for another measured value. 

여러분의 의견을 기다리겠습니다!
문의하기

기술 세부 정보

Current ouput: 2 x 4…20 mA
센서 연결: 아날로그
승인: FM, IECEx, NEPSI
제품 라인: Stratos, Stratos Pro
측정 파라미터 : 전도도(유도식)
통신(출력, 디지털): HART
폭발 방지: Ex, Ex Zone 2

다운로드

Manuals

[13555] Transmitter Specific HART Command Specification
Stratos Pro A201 CondI
Device Revision: 02
[17288] Transmitter Specific HART Command Specification
Stratos Pro A201 CondI
Device Revision 04
[3938] 사용 설명서
Stratos Pro A201CONDI
유도성 전도도 Toroidal 센서를 이용한 전도도 측정
Version 04
[13752] Transmitter Specific HART Command Specification
Stratos Pro A201 CondI
Device Revision 03

브로셔

[14695] Brochure
Stratos Pro
2-wire analyzers for pH/ORP, conductivity or oxygen
[13209] 브로셔
Memosens@Knick

데이터 시트

[16180] 데이터 시트
Stratos Pro A201
제품 설명 | 명세서 | 제품 범위

인증서

[12917] Quality Control Certificate
Device Settings for Customer-Specific Buffer Solutions
Version 01
[17027] EU Type-Examination Certificate
No. KEMA 08ATEX0100 | 2024-03-07
Issue No. 10
Stratos Pro Types A201X…, A201X-*-0-T6, A211X…, A221X… and A231X… | Stratos Multi Type E401X
[8586] Certificado de Conformidade Ex (INMETRO, NCC)
Stratos Pro Types A201X…, A201X-*-0-T6, A211X…, A201B..., A221X…, A231X…, Stratos Multi Type E401X
No. NCC 11.7463 | Issue No 6
Validity date 2027-05-11
[9523] Certitficate of Conformity (China - Ex NEPSI)
Cert No. GYJ20.1053X | 2020-06-10
Stratos Pro A2..B
[8682] Certificate of Compliance (FM)
No. FM21US0078 | 2023-11-02
Stratos Multi E401X…, Stratos Pro A201X…, A211X…, A201B…, A221X…, A231X
[17021] IECEx Certificate of Conformity
No. IECEX KEM 08.0020
Issue No. 9 | 2024-03-07
Stratos Pro Types A201X…, A201X-*-0-T6, A211X…, A201B…, A221X…, A231X | Stratos Multi Type E401X
[8040] Certificate of Conformity (FM-Canada)
No. FM21CA0052 (Canada) | 2021-11-01
Stratos Pro Types A201X…, A211X…, A201B…, A221X… and A231X… | Stratos Multi Type E401X

Safety guides

[7598] Safety Guide
Stratos Pro / MS / Evo Series
Installation and Use in Hazardous Locations
Version 05

제어 도면

[13023] Control Drawing
Stratos Pro Types A201X..., A211X..., A201B...
Zeichnungsnummer 212.002-100 page 1 rev.8
ATEX, IECEx
[13028] Control Drawing
Stratos Pro Type A20.X... or A21.X... | A20.B... or A21.B...
Zeichnungsnummer 212.110-066 page 2 rev.0
cFMus

Software

[12232] EDD (AMS)
Stratos Pro A201 CondI
Device Revision 02
[18054] Software
KnUT (Knick Update Tool)
[17276] EDD (PDM)
Stratos Pro A201 CondI
Device Revision 04(02)
[17270] EDD (AMS)
Stratos Pro A201 CondI
Device Revision 04(03)
[17282] DTM (Pactware)
Stratos Pro A201 CondI
Device Revision 04
[12239] EDD (PDM)
Stratos Pro A201 CondI
Device Revision 02
[13537] DTM (Pactware)
Stratos Pro A201 CondI
Device Revision 03
[13542] EDD (PDM)
Stratos Pro A201 CondI
Device Revision 03
[13550] EDD (AMS)
Stratos Pro A201 CondI
Device Revision 03

서비스

Lorem lorem ipsum ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet. Lorem ipsum dolor sit amet, consetetur sadipscing elitr, sed diam nonumy eirmod tempor invidunt ut labore et dolore magna aliquyam erat, sed diam voluptua. At vero eos et accusam et justo duo dolores et ea rebum. Stet clita kasd gubergren, no sea takimata sanctus est Lorem ipsum dolor sit amet.

프로세스 또는 애플리케이션에서 사용

Cooling towers are used in a range of industrial sectors for diverting process heat from cooling circuits. Mineral deposits and corrosion reduce efficiency and lead to the premature wear of system components…

관련 제품

제품 갤러리 건너뛰기

관련 블로그 게시물

Robust WA111 Retractable Fitting Made of Plastic for Highly Corrosive Operating Conditions

The plastic WA111 retractable fitting is a robust and cost-effective solution for corrosive processes and environments. It is equipped with a secure lock function and multiple nozzles for thorough sensor cleaning.

Successful joint project : Knick developed the special Ceramat WA 155 retractable fitting for optical probes from SOPAT

In cooperation with SOPAT, Knick developed a special Ceramat fitting for optical probes for automatic cleaning in fouling processes.

(현장에서) 휴대용으로 사용할 수 있는 고품질의 침적식 피팅

저희 Knick Elektronische Messgeräte GmbH & Co. KG는 pH, 전도도 및 용존 산소의 휴대용 측정에 사용할 수 있는 침적식 피팅 ARD 170을 출시합니다. 제품을 설계 시, 간단하고 유연한 취급이 가능하도록 심혈을 기울였습니다.

방폭 지역에서의 사용을 위한 전기 전도성이 있는 버전의

저희 Knick Elektronische Messgeräte GmbH & Co. KG는 전기 전도성이 있는 버전(EL)의 침적식 피팅 ARD 50 EL 및 ARD 75 EL의 출시를 통해 액상 분석용 피팅의 포트폴리오를 확장했습니다. 이 2개의 산업용 피팅은 모듈식 구조로 되어있어 응용 분야에 맞는 센서를 선택할 수 있는 폭이 넓습니다.

How to get the sensor into the process

Sensors as the direct interface to the process must be exactly matched to the chemistry of the measured medium and to the prevailing pressure and temperature conditions.